Changing Out a “Vintage” Dimmer SwitchTrying to identify these wires on a switchIs my CL dimmer compatible with my light switch fixture?Dimmer switch gets very warm - almost hotReplacing single pole light switch with dimmerChanging out programmable Light Switch, wire help needed!Replacing 3-way dimmer switch with 3-way switchElectrical: Wiring a dimmer switch in a circuit with fixture, outlet, another switch powering 2 other fixturesInstalling a smart dimmer switch into 3 gang boxWhy does my LED light flicker when turning it on using a dimmer switch?Wiring Z-wave Dimmer switch into 2-gang switch setup

How to initiate a conversation with a person who recently had transition but you were not in touch with them?

Non-differentiable Lipschitz functions

numpy 1D array: mask elements that repeat more than n times

What is the best focal length for DSLR film negative scan?

Do animals summoned by the Conjure Animals spell get extra HP from Circle of the Shepherd's Spirit Totem ability?

Where do overtones in a 555 generated square wave come from?

What are some examples of three-mora atamadaka verbs besides 帰る?

What's wrong with this proof of almost sure limits?

Double feature: Weightier

How does AT-AT deploy troops?

Windows 10 computer waking up from sleep

What is the sum of the reciprocals of the squares of the hypotenuse of all Pythagorean triangles?

Travel with Expired Greek Passport from UK to Greece and Return

Why does `print <$> (print "hello")` print "hello"?

On the finite simple groups with an irreducible complex representation of a given dimension

Impeachment jury tampering

Migrate foreign key type from char to binary - ways to deal with the fallout?

who is the owner of Loan money paid back to bank

Can someone still get the title of "Club Master?"

Is Dom based XSS still a valid security concern in modern browsers?

Are the Shimano derailleurs sold on Ali Express genuine or fake?

What to do with developers who don't follow requirements?

Why is the Falcon Heavy center core recovery done at sea?

What is the "more" means here?



Changing Out a “Vintage” Dimmer Switch


Trying to identify these wires on a switchIs my CL dimmer compatible with my light switch fixture?Dimmer switch gets very warm - almost hotReplacing single pole light switch with dimmerChanging out programmable Light Switch, wire help needed!Replacing 3-way dimmer switch with 3-way switchElectrical: Wiring a dimmer switch in a circuit with fixture, outlet, another switch powering 2 other fixturesInstalling a smart dimmer switch into 3 gang boxWhy does my LED light flicker when turning it on using a dimmer switch?Wiring Z-wave Dimmer switch into 2-gang switch setup






.everyoneloves__top-leaderboard:empty,.everyoneloves__mid-leaderboard:empty,.everyoneloves__bot-mid-leaderboard:empty
margin-bottom:0;









7

















First off ---- I am by no means an electrician.



That said, I have a dimmer switch that needs to go..and be replaced by a new one. However, upon searching the internet and reading the instructions several times over, I am stuck. The dimmer being replaced is from 1978 (original to the house). I have attached photos of the new one, the old one (still attached the house) and the instructions. All the help they have been was saying, "consult an electrician if what is on the wall doesn't match the paper..."



Please note that the wires attached to the switch are all black, they just have over-spray from painting on them. Additionally, there is a ground in the back but I don't know which is the positive or which is the negative.



I appreciate any and all help! I can easily provide more pictures if needed or information.



enter image description hereenter image description hereenter image description hereenter image description hereenter image description hereenter image description hereenter image description here










share|improve this question





















  • 1





    @Jim Stewart, I just answered assuming no neutral needed. Where on the new dimmer do you see a neutral terminal?

    – Jimmy Fix-it
    Jun 6 at 2:00






  • 1





    There is only one fixture on the circuit.

    – J Crosby
    Jun 6 at 2:07






  • 2





    @JimStewart the new one does not need neutral.

    – Harper
    Jun 6 at 6:51






  • 2





    @Criggie, it's not about "shame" in asking for a pro to do it. It's about wanting to learn. I have changed out switches before and outlets too. But those were always in newer builds (like no older than 2013) so I have simply not seen the way this box was tied in before. I have no problem calling a pro when I need it. But I know with a little guidance (which numerous people have provided here) I can do it safely and not burn down my house.

    – J Crosby
    Jun 6 at 14:31






  • 4





    Just a quick note, in AC (alternating current) wiring, you don't really use the terms "positive" and "negative". It's normally talked about in terms of hot, neutral and ground. Reason being is that the current switches between positive and negative 50-60 times per second (depending on where you are in the world).

    – JPhi1618
    Jun 6 at 16:03

















7

















First off ---- I am by no means an electrician.



That said, I have a dimmer switch that needs to go..and be replaced by a new one. However, upon searching the internet and reading the instructions several times over, I am stuck. The dimmer being replaced is from 1978 (original to the house). I have attached photos of the new one, the old one (still attached the house) and the instructions. All the help they have been was saying, "consult an electrician if what is on the wall doesn't match the paper..."



Please note that the wires attached to the switch are all black, they just have over-spray from painting on them. Additionally, there is a ground in the back but I don't know which is the positive or which is the negative.



I appreciate any and all help! I can easily provide more pictures if needed or information.



enter image description hereenter image description hereenter image description hereenter image description hereenter image description hereenter image description hereenter image description here










share|improve this question





















  • 1





    @Jim Stewart, I just answered assuming no neutral needed. Where on the new dimmer do you see a neutral terminal?

    – Jimmy Fix-it
    Jun 6 at 2:00






  • 1





    There is only one fixture on the circuit.

    – J Crosby
    Jun 6 at 2:07






  • 2





    @JimStewart the new one does not need neutral.

    – Harper
    Jun 6 at 6:51






  • 2





    @Criggie, it's not about "shame" in asking for a pro to do it. It's about wanting to learn. I have changed out switches before and outlets too. But those were always in newer builds (like no older than 2013) so I have simply not seen the way this box was tied in before. I have no problem calling a pro when I need it. But I know with a little guidance (which numerous people have provided here) I can do it safely and not burn down my house.

    – J Crosby
    Jun 6 at 14:31






  • 4





    Just a quick note, in AC (alternating current) wiring, you don't really use the terms "positive" and "negative". It's normally talked about in terms of hot, neutral and ground. Reason being is that the current switches between positive and negative 50-60 times per second (depending on where you are in the world).

    – JPhi1618
    Jun 6 at 16:03













7












7








7








First off ---- I am by no means an electrician.



That said, I have a dimmer switch that needs to go..and be replaced by a new one. However, upon searching the internet and reading the instructions several times over, I am stuck. The dimmer being replaced is from 1978 (original to the house). I have attached photos of the new one, the old one (still attached the house) and the instructions. All the help they have been was saying, "consult an electrician if what is on the wall doesn't match the paper..."



Please note that the wires attached to the switch are all black, they just have over-spray from painting on them. Additionally, there is a ground in the back but I don't know which is the positive or which is the negative.



I appreciate any and all help! I can easily provide more pictures if needed or information.



enter image description hereenter image description hereenter image description hereenter image description hereenter image description hereenter image description hereenter image description here










share|improve this question















First off ---- I am by no means an electrician.



That said, I have a dimmer switch that needs to go..and be replaced by a new one. However, upon searching the internet and reading the instructions several times over, I am stuck. The dimmer being replaced is from 1978 (original to the house). I have attached photos of the new one, the old one (still attached the house) and the instructions. All the help they have been was saying, "consult an electrician if what is on the wall doesn't match the paper..."



Please note that the wires attached to the switch are all black, they just have over-spray from painting on them. Additionally, there is a ground in the back but I don't know which is the positive or which is the negative.



I appreciate any and all help! I can easily provide more pictures if needed or information.



enter image description hereenter image description hereenter image description hereenter image description hereenter image description hereenter image description hereenter image description here







electrical lighting dimmer-switch






share|improve this question














share|improve this question











share|improve this question




share|improve this question










asked Jun 6 at 1:05









J CrosbyJ Crosby

2861 silver badge16 bronze badges




2861 silver badge16 bronze badges










  • 1





    @Jim Stewart, I just answered assuming no neutral needed. Where on the new dimmer do you see a neutral terminal?

    – Jimmy Fix-it
    Jun 6 at 2:00






  • 1





    There is only one fixture on the circuit.

    – J Crosby
    Jun 6 at 2:07






  • 2





    @JimStewart the new one does not need neutral.

    – Harper
    Jun 6 at 6:51






  • 2





    @Criggie, it's not about "shame" in asking for a pro to do it. It's about wanting to learn. I have changed out switches before and outlets too. But those were always in newer builds (like no older than 2013) so I have simply not seen the way this box was tied in before. I have no problem calling a pro when I need it. But I know with a little guidance (which numerous people have provided here) I can do it safely and not burn down my house.

    – J Crosby
    Jun 6 at 14:31






  • 4





    Just a quick note, in AC (alternating current) wiring, you don't really use the terms "positive" and "negative". It's normally talked about in terms of hot, neutral and ground. Reason being is that the current switches between positive and negative 50-60 times per second (depending on where you are in the world).

    – JPhi1618
    Jun 6 at 16:03












  • 1





    @Jim Stewart, I just answered assuming no neutral needed. Where on the new dimmer do you see a neutral terminal?

    – Jimmy Fix-it
    Jun 6 at 2:00






  • 1





    There is only one fixture on the circuit.

    – J Crosby
    Jun 6 at 2:07






  • 2





    @JimStewart the new one does not need neutral.

    – Harper
    Jun 6 at 6:51






  • 2





    @Criggie, it's not about "shame" in asking for a pro to do it. It's about wanting to learn. I have changed out switches before and outlets too. But those were always in newer builds (like no older than 2013) so I have simply not seen the way this box was tied in before. I have no problem calling a pro when I need it. But I know with a little guidance (which numerous people have provided here) I can do it safely and not burn down my house.

    – J Crosby
    Jun 6 at 14:31






  • 4





    Just a quick note, in AC (alternating current) wiring, you don't really use the terms "positive" and "negative". It's normally talked about in terms of hot, neutral and ground. Reason being is that the current switches between positive and negative 50-60 times per second (depending on where you are in the world).

    – JPhi1618
    Jun 6 at 16:03







1




1





@Jim Stewart, I just answered assuming no neutral needed. Where on the new dimmer do you see a neutral terminal?

– Jimmy Fix-it
Jun 6 at 2:00





@Jim Stewart, I just answered assuming no neutral needed. Where on the new dimmer do you see a neutral terminal?

– Jimmy Fix-it
Jun 6 at 2:00




1




1





There is only one fixture on the circuit.

– J Crosby
Jun 6 at 2:07





There is only one fixture on the circuit.

– J Crosby
Jun 6 at 2:07




2




2





@JimStewart the new one does not need neutral.

– Harper
Jun 6 at 6:51





@JimStewart the new one does not need neutral.

– Harper
Jun 6 at 6:51




2




2





@Criggie, it's not about "shame" in asking for a pro to do it. It's about wanting to learn. I have changed out switches before and outlets too. But those were always in newer builds (like no older than 2013) so I have simply not seen the way this box was tied in before. I have no problem calling a pro when I need it. But I know with a little guidance (which numerous people have provided here) I can do it safely and not burn down my house.

– J Crosby
Jun 6 at 14:31





@Criggie, it's not about "shame" in asking for a pro to do it. It's about wanting to learn. I have changed out switches before and outlets too. But those were always in newer builds (like no older than 2013) so I have simply not seen the way this box was tied in before. I have no problem calling a pro when I need it. But I know with a little guidance (which numerous people have provided here) I can do it safely and not burn down my house.

– J Crosby
Jun 6 at 14:31




4




4





Just a quick note, in AC (alternating current) wiring, you don't really use the terms "positive" and "negative". It's normally talked about in terms of hot, neutral and ground. Reason being is that the current switches between positive and negative 50-60 times per second (depending on where you are in the world).

– JPhi1618
Jun 6 at 16:03





Just a quick note, in AC (alternating current) wiring, you don't really use the terms "positive" and "negative". It's normally talked about in terms of hot, neutral and ground. Reason being is that the current switches between positive and negative 50-60 times per second (depending on where you are in the world).

– JPhi1618
Jun 6 at 16:03










2 Answers
2






active

oldest

votes


















9


















You have a "single-pole" arrangement, i.e. one switch controlling the load (the light). You simply need to turn off the circuit breaker controlling this circuit, remove the two wires from your existing dimmer switch and place them on the two wire terminals on the new dimmer switch (the terminals that are NOT green). It does not matter which wire goes to which terminal.



There does appear to be a ground wire (bare) under a screw in the back of the box; if possible you should attach a short green or bare wire from the green terminal on the new dimmer to that same screw (or alternate ground screw) in the back of the box. This is not required for the new switch to work; it is a safety feature.



Attach the dimmer and cover plate to the box, then turn the circuit breaker on. Done.






share|improve this answer























  • 2





    The ground is not necessary. A switch can ground via the metal box and mounting screws.

    – Harper
    Jun 6 at 6:48






  • 1





    From the looks of that box there is no hope of pigtailing onto that ground. Also looks like the grounds are not tied together but connect only through the box - that's definitely not allowed anymore. Drives me mad, mid-century electricians... never leave enough wire in the box and cut the grounds down to little stumps. If you're lucky you can sometimes pull enough staples to fish yourself an extra length from the wall. In this case it's not strictly necessary, but it kills me when crap workmanship turns a five minute job into a weekend teardown.

    – J...
    Jun 6 at 11:44












  • @J... so you are saying that I shouldn't try to tie in some extra ground wire (which I happen to have) into the existing ground? Other than the obvious (the set screw may not be long enough) why is that?

    – J Crosby
    Jun 6 at 14:11






  • 1





    @JCrosby No, you'll get sufficient grounding from the metal screw attachment. It's not ideal, but it's allowed and reasonably fine. Trying to mess with those ground stumps will just be more headache than it's worth. Critically, it looks like downstream grounding is relying on those back-box connections so if they're firmly in place as it is I wouldn't risk breaking those connections only to re-make them worse than they already are. To fix it properly you would need to pull more wire into the box (if there's enough in the wall) so that you had enough ground wire to pigtail them all together.

    – J...
    Jun 6 at 14:18


















6


















Based on the instructions and Single Pole installation (i.e., one switch rather than 2 switches), this should be quite simple:



Line - Hot



This is one of your black wires. Hard to tell from the old dimmer *and it may not have made any difference on the old dimmer which wire was hot and which wire was switched hot. It might not matter on the dimmer, but you would have to read the rest of the instructions to figure that out. If it does matter, you can tell by turning the old dimmer off and then checking with a non-contact tester. Whichever wire lights up is hot and the other is switched hot.



Neutral



The installation instructions mention neutral but don't actually use it. So you can ignore that. As it turns out, you do appear to have neutral (the whites all together), which matches the diagram, but it actually doesn't matter in this particular case.



Ground



If you don't have any ground wires then you can, provided everything else was done right (ha ha ha!), ground to the metal box using a ground screw with a pigtail like. However, with switches (as I understand it, for some reason, not with receptacles), you can ground from the metal switch yoke to a metal box by simply screwing it in place, provided there is no paint on the box or paper spacer on the screws or anything else that would prevent a solid, electrically conductive, connection.



Load - Switched Hot



This is the "other" black wire.



As far as "all black": Hot, switched hot and traveler (for 3-way switches) can be any colors except: White (allowed in certain situations), Gray, Green or bare wire. Black + White is the most common type of cable, so "all black" is typical, albeit confusing. But even if the colors were Blue & Red, that wouldn't actually be any more informative.






share|improve this answer























  • 3





    No need to run a ground wire, it will ground via the mounting screws to the metal box.

    – Harper
    Jun 6 at 6:49






  • 3





    There does appear to be a ground-wire connected to the box. You can barely see it in the 4th picture.

    – JimmyJames
    Jun 6 at 15:59






  • 1





    In fact, there appears to be a second ground screw in the back of the box next to the one that's tied into the house ground. I suppose you could run a green or bare copper pigtail from that to the dimmer. Given the apparent corrosion on the screw tabs, I'd be in favor of that over relying on the dimmer's metal plate to make good electrical contact with the box.

    – Adrian McCarthy
    Jun 6 at 19:34











  • @Harper: that's true if and only if you remove the insulating paper washers, but it's still better to attach a ground wire.

    – Timbo
    Jun 6 at 19:50






  • 1





    @Timbo in that installation the drywall ears will hold the yoke proud of the box, and the washers will be irrelevant. (And the grounding path unsuitable for a receptacle, regardless). Metal-metal contact yoke to box is not required for switches.

    – Harper
    Jun 6 at 19:59













Your Answer








StackExchange.ready(function()
var channelOptions =
tags: "".split(" "),
id: "73"
;
initTagRenderer("".split(" "), "".split(" "), channelOptions);

StackExchange.using("externalEditor", function()
// Have to fire editor after snippets, if snippets enabled
if (StackExchange.settings.snippets.snippetsEnabled)
StackExchange.using("snippets", function()
createEditor();
);

else
createEditor();

);

function createEditor()
StackExchange.prepareEditor(
heartbeatType: 'answer',
autoActivateHeartbeat: false,
convertImagesToLinks: false,
noModals: true,
showLowRepImageUploadWarning: true,
reputationToPostImages: null,
bindNavPrevention: true,
postfix: "",
imageUploader:
brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/4.0/"u003ecc by-sa 4.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
allowUrls: true
,
noCode: true, onDemand: true,
discardSelector: ".discard-answer"
,immediatelyShowMarkdownHelp:true
);



);














draft saved

draft discarded
















StackExchange.ready(
function ()
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdiy.stackexchange.com%2fquestions%2f166670%2fchanging-out-a-vintage-dimmer-switch%23new-answer', 'question_page');

);

Post as a guest















Required, but never shown


























2 Answers
2






active

oldest

votes








2 Answers
2






active

oldest

votes









active

oldest

votes






active

oldest

votes









9


















You have a "single-pole" arrangement, i.e. one switch controlling the load (the light). You simply need to turn off the circuit breaker controlling this circuit, remove the two wires from your existing dimmer switch and place them on the two wire terminals on the new dimmer switch (the terminals that are NOT green). It does not matter which wire goes to which terminal.



There does appear to be a ground wire (bare) under a screw in the back of the box; if possible you should attach a short green or bare wire from the green terminal on the new dimmer to that same screw (or alternate ground screw) in the back of the box. This is not required for the new switch to work; it is a safety feature.



Attach the dimmer and cover plate to the box, then turn the circuit breaker on. Done.






share|improve this answer























  • 2





    The ground is not necessary. A switch can ground via the metal box and mounting screws.

    – Harper
    Jun 6 at 6:48






  • 1





    From the looks of that box there is no hope of pigtailing onto that ground. Also looks like the grounds are not tied together but connect only through the box - that's definitely not allowed anymore. Drives me mad, mid-century electricians... never leave enough wire in the box and cut the grounds down to little stumps. If you're lucky you can sometimes pull enough staples to fish yourself an extra length from the wall. In this case it's not strictly necessary, but it kills me when crap workmanship turns a five minute job into a weekend teardown.

    – J...
    Jun 6 at 11:44












  • @J... so you are saying that I shouldn't try to tie in some extra ground wire (which I happen to have) into the existing ground? Other than the obvious (the set screw may not be long enough) why is that?

    – J Crosby
    Jun 6 at 14:11






  • 1





    @JCrosby No, you'll get sufficient grounding from the metal screw attachment. It's not ideal, but it's allowed and reasonably fine. Trying to mess with those ground stumps will just be more headache than it's worth. Critically, it looks like downstream grounding is relying on those back-box connections so if they're firmly in place as it is I wouldn't risk breaking those connections only to re-make them worse than they already are. To fix it properly you would need to pull more wire into the box (if there's enough in the wall) so that you had enough ground wire to pigtail them all together.

    – J...
    Jun 6 at 14:18















9


















You have a "single-pole" arrangement, i.e. one switch controlling the load (the light). You simply need to turn off the circuit breaker controlling this circuit, remove the two wires from your existing dimmer switch and place them on the two wire terminals on the new dimmer switch (the terminals that are NOT green). It does not matter which wire goes to which terminal.



There does appear to be a ground wire (bare) under a screw in the back of the box; if possible you should attach a short green or bare wire from the green terminal on the new dimmer to that same screw (or alternate ground screw) in the back of the box. This is not required for the new switch to work; it is a safety feature.



Attach the dimmer and cover plate to the box, then turn the circuit breaker on. Done.






share|improve this answer























  • 2





    The ground is not necessary. A switch can ground via the metal box and mounting screws.

    – Harper
    Jun 6 at 6:48






  • 1





    From the looks of that box there is no hope of pigtailing onto that ground. Also looks like the grounds are not tied together but connect only through the box - that's definitely not allowed anymore. Drives me mad, mid-century electricians... never leave enough wire in the box and cut the grounds down to little stumps. If you're lucky you can sometimes pull enough staples to fish yourself an extra length from the wall. In this case it's not strictly necessary, but it kills me when crap workmanship turns a five minute job into a weekend teardown.

    – J...
    Jun 6 at 11:44












  • @J... so you are saying that I shouldn't try to tie in some extra ground wire (which I happen to have) into the existing ground? Other than the obvious (the set screw may not be long enough) why is that?

    – J Crosby
    Jun 6 at 14:11






  • 1





    @JCrosby No, you'll get sufficient grounding from the metal screw attachment. It's not ideal, but it's allowed and reasonably fine. Trying to mess with those ground stumps will just be more headache than it's worth. Critically, it looks like downstream grounding is relying on those back-box connections so if they're firmly in place as it is I wouldn't risk breaking those connections only to re-make them worse than they already are. To fix it properly you would need to pull more wire into the box (if there's enough in the wall) so that you had enough ground wire to pigtail them all together.

    – J...
    Jun 6 at 14:18













9














9










9









You have a "single-pole" arrangement, i.e. one switch controlling the load (the light). You simply need to turn off the circuit breaker controlling this circuit, remove the two wires from your existing dimmer switch and place them on the two wire terminals on the new dimmer switch (the terminals that are NOT green). It does not matter which wire goes to which terminal.



There does appear to be a ground wire (bare) under a screw in the back of the box; if possible you should attach a short green or bare wire from the green terminal on the new dimmer to that same screw (or alternate ground screw) in the back of the box. This is not required for the new switch to work; it is a safety feature.



Attach the dimmer and cover plate to the box, then turn the circuit breaker on. Done.






share|improve this answer
















You have a "single-pole" arrangement, i.e. one switch controlling the load (the light). You simply need to turn off the circuit breaker controlling this circuit, remove the two wires from your existing dimmer switch and place them on the two wire terminals on the new dimmer switch (the terminals that are NOT green). It does not matter which wire goes to which terminal.



There does appear to be a ground wire (bare) under a screw in the back of the box; if possible you should attach a short green or bare wire from the green terminal on the new dimmer to that same screw (or alternate ground screw) in the back of the box. This is not required for the new switch to work; it is a safety feature.



Attach the dimmer and cover plate to the box, then turn the circuit breaker on. Done.







share|improve this answer















share|improve this answer




share|improve this answer








edited Jun 6 at 3:32

























answered Jun 6 at 1:57









Jimmy Fix-itJimmy Fix-it

23.1k12 silver badges30 bronze badges




23.1k12 silver badges30 bronze badges










  • 2





    The ground is not necessary. A switch can ground via the metal box and mounting screws.

    – Harper
    Jun 6 at 6:48






  • 1





    From the looks of that box there is no hope of pigtailing onto that ground. Also looks like the grounds are not tied together but connect only through the box - that's definitely not allowed anymore. Drives me mad, mid-century electricians... never leave enough wire in the box and cut the grounds down to little stumps. If you're lucky you can sometimes pull enough staples to fish yourself an extra length from the wall. In this case it's not strictly necessary, but it kills me when crap workmanship turns a five minute job into a weekend teardown.

    – J...
    Jun 6 at 11:44












  • @J... so you are saying that I shouldn't try to tie in some extra ground wire (which I happen to have) into the existing ground? Other than the obvious (the set screw may not be long enough) why is that?

    – J Crosby
    Jun 6 at 14:11






  • 1





    @JCrosby No, you'll get sufficient grounding from the metal screw attachment. It's not ideal, but it's allowed and reasonably fine. Trying to mess with those ground stumps will just be more headache than it's worth. Critically, it looks like downstream grounding is relying on those back-box connections so if they're firmly in place as it is I wouldn't risk breaking those connections only to re-make them worse than they already are. To fix it properly you would need to pull more wire into the box (if there's enough in the wall) so that you had enough ground wire to pigtail them all together.

    – J...
    Jun 6 at 14:18












  • 2





    The ground is not necessary. A switch can ground via the metal box and mounting screws.

    – Harper
    Jun 6 at 6:48






  • 1





    From the looks of that box there is no hope of pigtailing onto that ground. Also looks like the grounds are not tied together but connect only through the box - that's definitely not allowed anymore. Drives me mad, mid-century electricians... never leave enough wire in the box and cut the grounds down to little stumps. If you're lucky you can sometimes pull enough staples to fish yourself an extra length from the wall. In this case it's not strictly necessary, but it kills me when crap workmanship turns a five minute job into a weekend teardown.

    – J...
    Jun 6 at 11:44












  • @J... so you are saying that I shouldn't try to tie in some extra ground wire (which I happen to have) into the existing ground? Other than the obvious (the set screw may not be long enough) why is that?

    – J Crosby
    Jun 6 at 14:11






  • 1





    @JCrosby No, you'll get sufficient grounding from the metal screw attachment. It's not ideal, but it's allowed and reasonably fine. Trying to mess with those ground stumps will just be more headache than it's worth. Critically, it looks like downstream grounding is relying on those back-box connections so if they're firmly in place as it is I wouldn't risk breaking those connections only to re-make them worse than they already are. To fix it properly you would need to pull more wire into the box (if there's enough in the wall) so that you had enough ground wire to pigtail them all together.

    – J...
    Jun 6 at 14:18







2




2





The ground is not necessary. A switch can ground via the metal box and mounting screws.

– Harper
Jun 6 at 6:48





The ground is not necessary. A switch can ground via the metal box and mounting screws.

– Harper
Jun 6 at 6:48




1




1





From the looks of that box there is no hope of pigtailing onto that ground. Also looks like the grounds are not tied together but connect only through the box - that's definitely not allowed anymore. Drives me mad, mid-century electricians... never leave enough wire in the box and cut the grounds down to little stumps. If you're lucky you can sometimes pull enough staples to fish yourself an extra length from the wall. In this case it's not strictly necessary, but it kills me when crap workmanship turns a five minute job into a weekend teardown.

– J...
Jun 6 at 11:44






From the looks of that box there is no hope of pigtailing onto that ground. Also looks like the grounds are not tied together but connect only through the box - that's definitely not allowed anymore. Drives me mad, mid-century electricians... never leave enough wire in the box and cut the grounds down to little stumps. If you're lucky you can sometimes pull enough staples to fish yourself an extra length from the wall. In this case it's not strictly necessary, but it kills me when crap workmanship turns a five minute job into a weekend teardown.

– J...
Jun 6 at 11:44














@J... so you are saying that I shouldn't try to tie in some extra ground wire (which I happen to have) into the existing ground? Other than the obvious (the set screw may not be long enough) why is that?

– J Crosby
Jun 6 at 14:11





@J... so you are saying that I shouldn't try to tie in some extra ground wire (which I happen to have) into the existing ground? Other than the obvious (the set screw may not be long enough) why is that?

– J Crosby
Jun 6 at 14:11




1




1





@JCrosby No, you'll get sufficient grounding from the metal screw attachment. It's not ideal, but it's allowed and reasonably fine. Trying to mess with those ground stumps will just be more headache than it's worth. Critically, it looks like downstream grounding is relying on those back-box connections so if they're firmly in place as it is I wouldn't risk breaking those connections only to re-make them worse than they already are. To fix it properly you would need to pull more wire into the box (if there's enough in the wall) so that you had enough ground wire to pigtail them all together.

– J...
Jun 6 at 14:18





@JCrosby No, you'll get sufficient grounding from the metal screw attachment. It's not ideal, but it's allowed and reasonably fine. Trying to mess with those ground stumps will just be more headache than it's worth. Critically, it looks like downstream grounding is relying on those back-box connections so if they're firmly in place as it is I wouldn't risk breaking those connections only to re-make them worse than they already are. To fix it properly you would need to pull more wire into the box (if there's enough in the wall) so that you had enough ground wire to pigtail them all together.

– J...
Jun 6 at 14:18













6


















Based on the instructions and Single Pole installation (i.e., one switch rather than 2 switches), this should be quite simple:



Line - Hot



This is one of your black wires. Hard to tell from the old dimmer *and it may not have made any difference on the old dimmer which wire was hot and which wire was switched hot. It might not matter on the dimmer, but you would have to read the rest of the instructions to figure that out. If it does matter, you can tell by turning the old dimmer off and then checking with a non-contact tester. Whichever wire lights up is hot and the other is switched hot.



Neutral



The installation instructions mention neutral but don't actually use it. So you can ignore that. As it turns out, you do appear to have neutral (the whites all together), which matches the diagram, but it actually doesn't matter in this particular case.



Ground



If you don't have any ground wires then you can, provided everything else was done right (ha ha ha!), ground to the metal box using a ground screw with a pigtail like. However, with switches (as I understand it, for some reason, not with receptacles), you can ground from the metal switch yoke to a metal box by simply screwing it in place, provided there is no paint on the box or paper spacer on the screws or anything else that would prevent a solid, electrically conductive, connection.



Load - Switched Hot



This is the "other" black wire.



As far as "all black": Hot, switched hot and traveler (for 3-way switches) can be any colors except: White (allowed in certain situations), Gray, Green or bare wire. Black + White is the most common type of cable, so "all black" is typical, albeit confusing. But even if the colors were Blue & Red, that wouldn't actually be any more informative.






share|improve this answer























  • 3





    No need to run a ground wire, it will ground via the mounting screws to the metal box.

    – Harper
    Jun 6 at 6:49






  • 3





    There does appear to be a ground-wire connected to the box. You can barely see it in the 4th picture.

    – JimmyJames
    Jun 6 at 15:59






  • 1





    In fact, there appears to be a second ground screw in the back of the box next to the one that's tied into the house ground. I suppose you could run a green or bare copper pigtail from that to the dimmer. Given the apparent corrosion on the screw tabs, I'd be in favor of that over relying on the dimmer's metal plate to make good electrical contact with the box.

    – Adrian McCarthy
    Jun 6 at 19:34











  • @Harper: that's true if and only if you remove the insulating paper washers, but it's still better to attach a ground wire.

    – Timbo
    Jun 6 at 19:50






  • 1





    @Timbo in that installation the drywall ears will hold the yoke proud of the box, and the washers will be irrelevant. (And the grounding path unsuitable for a receptacle, regardless). Metal-metal contact yoke to box is not required for switches.

    – Harper
    Jun 6 at 19:59
















6


















Based on the instructions and Single Pole installation (i.e., one switch rather than 2 switches), this should be quite simple:



Line - Hot



This is one of your black wires. Hard to tell from the old dimmer *and it may not have made any difference on the old dimmer which wire was hot and which wire was switched hot. It might not matter on the dimmer, but you would have to read the rest of the instructions to figure that out. If it does matter, you can tell by turning the old dimmer off and then checking with a non-contact tester. Whichever wire lights up is hot and the other is switched hot.



Neutral



The installation instructions mention neutral but don't actually use it. So you can ignore that. As it turns out, you do appear to have neutral (the whites all together), which matches the diagram, but it actually doesn't matter in this particular case.



Ground



If you don't have any ground wires then you can, provided everything else was done right (ha ha ha!), ground to the metal box using a ground screw with a pigtail like. However, with switches (as I understand it, for some reason, not with receptacles), you can ground from the metal switch yoke to a metal box by simply screwing it in place, provided there is no paint on the box or paper spacer on the screws or anything else that would prevent a solid, electrically conductive, connection.



Load - Switched Hot



This is the "other" black wire.



As far as "all black": Hot, switched hot and traveler (for 3-way switches) can be any colors except: White (allowed in certain situations), Gray, Green or bare wire. Black + White is the most common type of cable, so "all black" is typical, albeit confusing. But even if the colors were Blue & Red, that wouldn't actually be any more informative.






share|improve this answer























  • 3





    No need to run a ground wire, it will ground via the mounting screws to the metal box.

    – Harper
    Jun 6 at 6:49






  • 3





    There does appear to be a ground-wire connected to the box. You can barely see it in the 4th picture.

    – JimmyJames
    Jun 6 at 15:59






  • 1





    In fact, there appears to be a second ground screw in the back of the box next to the one that's tied into the house ground. I suppose you could run a green or bare copper pigtail from that to the dimmer. Given the apparent corrosion on the screw tabs, I'd be in favor of that over relying on the dimmer's metal plate to make good electrical contact with the box.

    – Adrian McCarthy
    Jun 6 at 19:34











  • @Harper: that's true if and only if you remove the insulating paper washers, but it's still better to attach a ground wire.

    – Timbo
    Jun 6 at 19:50






  • 1





    @Timbo in that installation the drywall ears will hold the yoke proud of the box, and the washers will be irrelevant. (And the grounding path unsuitable for a receptacle, regardless). Metal-metal contact yoke to box is not required for switches.

    – Harper
    Jun 6 at 19:59














6














6










6









Based on the instructions and Single Pole installation (i.e., one switch rather than 2 switches), this should be quite simple:



Line - Hot



This is one of your black wires. Hard to tell from the old dimmer *and it may not have made any difference on the old dimmer which wire was hot and which wire was switched hot. It might not matter on the dimmer, but you would have to read the rest of the instructions to figure that out. If it does matter, you can tell by turning the old dimmer off and then checking with a non-contact tester. Whichever wire lights up is hot and the other is switched hot.



Neutral



The installation instructions mention neutral but don't actually use it. So you can ignore that. As it turns out, you do appear to have neutral (the whites all together), which matches the diagram, but it actually doesn't matter in this particular case.



Ground



If you don't have any ground wires then you can, provided everything else was done right (ha ha ha!), ground to the metal box using a ground screw with a pigtail like. However, with switches (as I understand it, for some reason, not with receptacles), you can ground from the metal switch yoke to a metal box by simply screwing it in place, provided there is no paint on the box or paper spacer on the screws or anything else that would prevent a solid, electrically conductive, connection.



Load - Switched Hot



This is the "other" black wire.



As far as "all black": Hot, switched hot and traveler (for 3-way switches) can be any colors except: White (allowed in certain situations), Gray, Green or bare wire. Black + White is the most common type of cable, so "all black" is typical, albeit confusing. But even if the colors were Blue & Red, that wouldn't actually be any more informative.






share|improve this answer
















Based on the instructions and Single Pole installation (i.e., one switch rather than 2 switches), this should be quite simple:



Line - Hot



This is one of your black wires. Hard to tell from the old dimmer *and it may not have made any difference on the old dimmer which wire was hot and which wire was switched hot. It might not matter on the dimmer, but you would have to read the rest of the instructions to figure that out. If it does matter, you can tell by turning the old dimmer off and then checking with a non-contact tester. Whichever wire lights up is hot and the other is switched hot.



Neutral



The installation instructions mention neutral but don't actually use it. So you can ignore that. As it turns out, you do appear to have neutral (the whites all together), which matches the diagram, but it actually doesn't matter in this particular case.



Ground



If you don't have any ground wires then you can, provided everything else was done right (ha ha ha!), ground to the metal box using a ground screw with a pigtail like. However, with switches (as I understand it, for some reason, not with receptacles), you can ground from the metal switch yoke to a metal box by simply screwing it in place, provided there is no paint on the box or paper spacer on the screws or anything else that would prevent a solid, electrically conductive, connection.



Load - Switched Hot



This is the "other" black wire.



As far as "all black": Hot, switched hot and traveler (for 3-way switches) can be any colors except: White (allowed in certain situations), Gray, Green or bare wire. Black + White is the most common type of cable, so "all black" is typical, albeit confusing. But even if the colors were Blue & Red, that wouldn't actually be any more informative.







share|improve this answer















share|improve this answer




share|improve this answer








edited Jun 6 at 13:58

























answered Jun 6 at 2:09









manassehkatzmanassehkatz

18.9k1 gold badge25 silver badges58 bronze badges




18.9k1 gold badge25 silver badges58 bronze badges










  • 3





    No need to run a ground wire, it will ground via the mounting screws to the metal box.

    – Harper
    Jun 6 at 6:49






  • 3





    There does appear to be a ground-wire connected to the box. You can barely see it in the 4th picture.

    – JimmyJames
    Jun 6 at 15:59






  • 1





    In fact, there appears to be a second ground screw in the back of the box next to the one that's tied into the house ground. I suppose you could run a green or bare copper pigtail from that to the dimmer. Given the apparent corrosion on the screw tabs, I'd be in favor of that over relying on the dimmer's metal plate to make good electrical contact with the box.

    – Adrian McCarthy
    Jun 6 at 19:34











  • @Harper: that's true if and only if you remove the insulating paper washers, but it's still better to attach a ground wire.

    – Timbo
    Jun 6 at 19:50






  • 1





    @Timbo in that installation the drywall ears will hold the yoke proud of the box, and the washers will be irrelevant. (And the grounding path unsuitable for a receptacle, regardless). Metal-metal contact yoke to box is not required for switches.

    – Harper
    Jun 6 at 19:59













  • 3





    No need to run a ground wire, it will ground via the mounting screws to the metal box.

    – Harper
    Jun 6 at 6:49






  • 3





    There does appear to be a ground-wire connected to the box. You can barely see it in the 4th picture.

    – JimmyJames
    Jun 6 at 15:59






  • 1





    In fact, there appears to be a second ground screw in the back of the box next to the one that's tied into the house ground. I suppose you could run a green or bare copper pigtail from that to the dimmer. Given the apparent corrosion on the screw tabs, I'd be in favor of that over relying on the dimmer's metal plate to make good electrical contact with the box.

    – Adrian McCarthy
    Jun 6 at 19:34











  • @Harper: that's true if and only if you remove the insulating paper washers, but it's still better to attach a ground wire.

    – Timbo
    Jun 6 at 19:50






  • 1





    @Timbo in that installation the drywall ears will hold the yoke proud of the box, and the washers will be irrelevant. (And the grounding path unsuitable for a receptacle, regardless). Metal-metal contact yoke to box is not required for switches.

    – Harper
    Jun 6 at 19:59








3




3





No need to run a ground wire, it will ground via the mounting screws to the metal box.

– Harper
Jun 6 at 6:49





No need to run a ground wire, it will ground via the mounting screws to the metal box.

– Harper
Jun 6 at 6:49




3




3





There does appear to be a ground-wire connected to the box. You can barely see it in the 4th picture.

– JimmyJames
Jun 6 at 15:59





There does appear to be a ground-wire connected to the box. You can barely see it in the 4th picture.

– JimmyJames
Jun 6 at 15:59




1




1





In fact, there appears to be a second ground screw in the back of the box next to the one that's tied into the house ground. I suppose you could run a green or bare copper pigtail from that to the dimmer. Given the apparent corrosion on the screw tabs, I'd be in favor of that over relying on the dimmer's metal plate to make good electrical contact with the box.

– Adrian McCarthy
Jun 6 at 19:34





In fact, there appears to be a second ground screw in the back of the box next to the one that's tied into the house ground. I suppose you could run a green or bare copper pigtail from that to the dimmer. Given the apparent corrosion on the screw tabs, I'd be in favor of that over relying on the dimmer's metal plate to make good electrical contact with the box.

– Adrian McCarthy
Jun 6 at 19:34













@Harper: that's true if and only if you remove the insulating paper washers, but it's still better to attach a ground wire.

– Timbo
Jun 6 at 19:50





@Harper: that's true if and only if you remove the insulating paper washers, but it's still better to attach a ground wire.

– Timbo
Jun 6 at 19:50




1




1





@Timbo in that installation the drywall ears will hold the yoke proud of the box, and the washers will be irrelevant. (And the grounding path unsuitable for a receptacle, regardless). Metal-metal contact yoke to box is not required for switches.

– Harper
Jun 6 at 19:59






@Timbo in that installation the drywall ears will hold the yoke proud of the box, and the washers will be irrelevant. (And the grounding path unsuitable for a receptacle, regardless). Metal-metal contact yoke to box is not required for switches.

– Harper
Jun 6 at 19:59



















draft saved

draft discarded















































Thanks for contributing an answer to Home Improvement Stack Exchange!


  • Please be sure to answer the question. Provide details and share your research!

But avoid


  • Asking for help, clarification, or responding to other answers.

  • Making statements based on opinion; back them up with references or personal experience.

To learn more, see our tips on writing great answers.




draft saved


draft discarded














StackExchange.ready(
function ()
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdiy.stackexchange.com%2fquestions%2f166670%2fchanging-out-a-vintage-dimmer-switch%23new-answer', 'question_page');

);

Post as a guest















Required, but never shown





















































Required, but never shown














Required, but never shown












Required, but never shown







Required, but never shown

































Required, but never shown














Required, but never shown












Required, but never shown







Required, but never shown









Popular posts from this blog

Distance measures on a map of a game The 2019 Stack Overflow Developer Survey Results Are Inmin distance in a graphShortest distance path on contour plotHow to plot a tilted map?Finding points outside of a diskDelaunay link distanceAnnulus from GeoDisks: drawing a ring on a mapNegative Correlation DistanceFind distance along a path (GPS coordinates)Finding position at given distance in a GeoPathMathematics behind distance estimation using camera

How to get a smooth, uniform ParametricPlot of a 2D Region?How to plot a complicated Region?How to exclude a region from ParametricPlotHow discretize a region placing vertices on a specific non-uniform gridHow to transform a Plot or a ParametricPlot into a RegionHow can I get a smooth plot of a bounded region?Smooth ParametricPlot3D with RegionFunction?Smooth border of a region ParametricPlotSmooth region boundarySmooth region plot from list of pointsGet minimum y of a certain x in a region

Genealogie vun de Merowenger Vum Merowech bis zum Chilperich I. | Navigatiounsmenü