Getting UPS Power from One Room to AnotherDoes one wall socket share power between both ac plugs?Could I use a UPS to power my humidifier on an underrated breaker with a little trickeryHow is power to an entire room restored by plugging something into an outlet in an adjacent room?Two power sources, one 3-way switch?Is it OK to run NM-B cable from outlet behind TV to surge protector?Ungrounded outlet indicates grounded when an UPS is plugged inUse small UPS to power steam boilerAn entire room lost powerWhy don't my devices have power after separating one room's wiring?Power outage in one room

Complex matrices column alignment on sign

KotH: Write a bot to play Grid Game

How does AT-AT deploy troops?

Why do the expressions for an object rolling down an incline not depend on the coefficient of static friction?

Radar Altimeter in Space Shuttle

Meaning of 'off one's brake fluid'

How did the T-850 still function after it removed its second battery?

Why combine commands on a single line in Bash script?

Getting unlimited amount of signatures - Risk?

How safe is it to leave my passport in my hotel room?

What's wrong with this proof of almost sure limits?

How does the Gameboy Link Cable work?

Can't delete polygon

How does a manufacturer determine the warranty for the battery?

18-month-old kicked out of church nursery

What are some examples of three-mora atamadaka verbs besides 帰る?

Hell0 W0rld! scored by ASCII values

Meaning of "in arms"

Dangers of being sympathetic to the killer

Right way to say I disagree with the design but ok I will do

How to initiate a conversation with a person who recently had transition but you were not in touch with them?

Where do overtones in a 555 generated square wave come from?

Can only rich people become president?

How can I find the weakness of our "Quality Assurance Process"?



Getting UPS Power from One Room to Another


Does one wall socket share power between both ac plugs?Could I use a UPS to power my humidifier on an underrated breaker with a little trickeryHow is power to an entire room restored by plugging something into an outlet in an adjacent room?Two power sources, one 3-way switch?Is it OK to run NM-B cable from outlet behind TV to surge protector?Ungrounded outlet indicates grounded when an UPS is plugged inUse small UPS to power steam boilerAn entire room lost powerWhy don't my devices have power after separating one room's wiring?Power outage in one room






.everyoneloves__top-leaderboard:empty,.everyoneloves__mid-leaderboard:empty,.everyoneloves__bot-mid-leaderboard:empty
margin-bottom:0;









16

















I’d like to run power from a Uninterruptible Power Supply (UPS) in ROOM A to where a work computer is used in ROOM B. I was thinking of installing an outlet box in ROOM A near where the UPS is plugged in, then run wire under the house to another outlet in the other room. That way I could just plug the UPS power out into the receptacle in ROOM A and the computer into the outlet in ROOM B on the other side of the house. Of course this line would not be connected to a circuit breaker, only from outlet to outlet.



I want to run the UPS to be available for use in both rooms, that’s the reason for the additional line.



Would there be any problems with this from a code perspective?
Would it require traditional wiring and hardware (e.g. Romex, outlet boxes) to accomplish it?










share|improve this question























  • 1





    You refer to "the receptacle in ROOM A". If that's a receptacle (aka female, aka socket), how do you intend to "plug the UPS power out" into it? The UPS output is also via receptacles.

    – Doug Deden
    Jun 5 at 22:16






  • 17





    @staticGenerator, good thing you've decided not to use a male-male cord -- those are extremely dangerous, since when either end is plugged in, the exposed prongs on the other end are hot. This could easily kill someone who doesn't realize this cord is "special".

    – Nate Strickland
    Jun 5 at 23:25






  • 12





    The male-to-male cord is commonly nicknamed "suicide cord", for the reason Nate has given.

    – donjuedo
    Jun 6 at 11:39






  • 4





    Is this an infrastructure sized UPS? Seriously, if it's not a UPS you need a forklift to move then just buy another one for ROOM B. It will cost you more to do what you are planning and you'll be far less likely to kill yourself or others.

    – J...
    Jun 6 at 12:26






  • 3





    @Adonalsium 3000VA is not small (for a house). It's much too big to even run on a standard 15A branch circuit. OP apparently also has a generator and just needs these UPSes to ride through generator startup. For just a desktop computer a little 600VA job would generally be fine and would barely cost more than materials, to say nothing of the work of installing the extension. Don't know about you, here in Canada 30m (ie:100ft) of 14/2 runs almost $60, and that doesn't count boxes and incidentals, drywall mud, paint, etc.

    – J...
    Jun 6 at 15:29


















16

















I’d like to run power from a Uninterruptible Power Supply (UPS) in ROOM A to where a work computer is used in ROOM B. I was thinking of installing an outlet box in ROOM A near where the UPS is plugged in, then run wire under the house to another outlet in the other room. That way I could just plug the UPS power out into the receptacle in ROOM A and the computer into the outlet in ROOM B on the other side of the house. Of course this line would not be connected to a circuit breaker, only from outlet to outlet.



I want to run the UPS to be available for use in both rooms, that’s the reason for the additional line.



Would there be any problems with this from a code perspective?
Would it require traditional wiring and hardware (e.g. Romex, outlet boxes) to accomplish it?










share|improve this question























  • 1





    You refer to "the receptacle in ROOM A". If that's a receptacle (aka female, aka socket), how do you intend to "plug the UPS power out" into it? The UPS output is also via receptacles.

    – Doug Deden
    Jun 5 at 22:16






  • 17





    @staticGenerator, good thing you've decided not to use a male-male cord -- those are extremely dangerous, since when either end is plugged in, the exposed prongs on the other end are hot. This could easily kill someone who doesn't realize this cord is "special".

    – Nate Strickland
    Jun 5 at 23:25






  • 12





    The male-to-male cord is commonly nicknamed "suicide cord", for the reason Nate has given.

    – donjuedo
    Jun 6 at 11:39






  • 4





    Is this an infrastructure sized UPS? Seriously, if it's not a UPS you need a forklift to move then just buy another one for ROOM B. It will cost you more to do what you are planning and you'll be far less likely to kill yourself or others.

    – J...
    Jun 6 at 12:26






  • 3





    @Adonalsium 3000VA is not small (for a house). It's much too big to even run on a standard 15A branch circuit. OP apparently also has a generator and just needs these UPSes to ride through generator startup. For just a desktop computer a little 600VA job would generally be fine and would barely cost more than materials, to say nothing of the work of installing the extension. Don't know about you, here in Canada 30m (ie:100ft) of 14/2 runs almost $60, and that doesn't count boxes and incidentals, drywall mud, paint, etc.

    – J...
    Jun 6 at 15:29














16












16








16


1






I’d like to run power from a Uninterruptible Power Supply (UPS) in ROOM A to where a work computer is used in ROOM B. I was thinking of installing an outlet box in ROOM A near where the UPS is plugged in, then run wire under the house to another outlet in the other room. That way I could just plug the UPS power out into the receptacle in ROOM A and the computer into the outlet in ROOM B on the other side of the house. Of course this line would not be connected to a circuit breaker, only from outlet to outlet.



I want to run the UPS to be available for use in both rooms, that’s the reason for the additional line.



Would there be any problems with this from a code perspective?
Would it require traditional wiring and hardware (e.g. Romex, outlet boxes) to accomplish it?










share|improve this question

















I’d like to run power from a Uninterruptible Power Supply (UPS) in ROOM A to where a work computer is used in ROOM B. I was thinking of installing an outlet box in ROOM A near where the UPS is plugged in, then run wire under the house to another outlet in the other room. That way I could just plug the UPS power out into the receptacle in ROOM A and the computer into the outlet in ROOM B on the other side of the house. Of course this line would not be connected to a circuit breaker, only from outlet to outlet.



I want to run the UPS to be available for use in both rooms, that’s the reason for the additional line.



Would there be any problems with this from a code perspective?
Would it require traditional wiring and hardware (e.g. Romex, outlet boxes) to accomplish it?







electrical wiring receptacle power-backup






share|improve this question
















share|improve this question













share|improve this question




share|improve this question








edited Jun 6 at 23:22









chicks

1492 silver badges12 bronze badges




1492 silver badges12 bronze badges










asked Jun 5 at 21:58









staticGeneratorstaticGenerator

831 silver badge5 bronze badges




831 silver badge5 bronze badges










  • 1





    You refer to "the receptacle in ROOM A". If that's a receptacle (aka female, aka socket), how do you intend to "plug the UPS power out" into it? The UPS output is also via receptacles.

    – Doug Deden
    Jun 5 at 22:16






  • 17





    @staticGenerator, good thing you've decided not to use a male-male cord -- those are extremely dangerous, since when either end is plugged in, the exposed prongs on the other end are hot. This could easily kill someone who doesn't realize this cord is "special".

    – Nate Strickland
    Jun 5 at 23:25






  • 12





    The male-to-male cord is commonly nicknamed "suicide cord", for the reason Nate has given.

    – donjuedo
    Jun 6 at 11:39






  • 4





    Is this an infrastructure sized UPS? Seriously, if it's not a UPS you need a forklift to move then just buy another one for ROOM B. It will cost you more to do what you are planning and you'll be far less likely to kill yourself or others.

    – J...
    Jun 6 at 12:26






  • 3





    @Adonalsium 3000VA is not small (for a house). It's much too big to even run on a standard 15A branch circuit. OP apparently also has a generator and just needs these UPSes to ride through generator startup. For just a desktop computer a little 600VA job would generally be fine and would barely cost more than materials, to say nothing of the work of installing the extension. Don't know about you, here in Canada 30m (ie:100ft) of 14/2 runs almost $60, and that doesn't count boxes and incidentals, drywall mud, paint, etc.

    – J...
    Jun 6 at 15:29













  • 1





    You refer to "the receptacle in ROOM A". If that's a receptacle (aka female, aka socket), how do you intend to "plug the UPS power out" into it? The UPS output is also via receptacles.

    – Doug Deden
    Jun 5 at 22:16






  • 17





    @staticGenerator, good thing you've decided not to use a male-male cord -- those are extremely dangerous, since when either end is plugged in, the exposed prongs on the other end are hot. This could easily kill someone who doesn't realize this cord is "special".

    – Nate Strickland
    Jun 5 at 23:25






  • 12





    The male-to-male cord is commonly nicknamed "suicide cord", for the reason Nate has given.

    – donjuedo
    Jun 6 at 11:39






  • 4





    Is this an infrastructure sized UPS? Seriously, if it's not a UPS you need a forklift to move then just buy another one for ROOM B. It will cost you more to do what you are planning and you'll be far less likely to kill yourself or others.

    – J...
    Jun 6 at 12:26






  • 3





    @Adonalsium 3000VA is not small (for a house). It's much too big to even run on a standard 15A branch circuit. OP apparently also has a generator and just needs these UPSes to ride through generator startup. For just a desktop computer a little 600VA job would generally be fine and would barely cost more than materials, to say nothing of the work of installing the extension. Don't know about you, here in Canada 30m (ie:100ft) of 14/2 runs almost $60, and that doesn't count boxes and incidentals, drywall mud, paint, etc.

    – J...
    Jun 6 at 15:29








1




1





You refer to "the receptacle in ROOM A". If that's a receptacle (aka female, aka socket), how do you intend to "plug the UPS power out" into it? The UPS output is also via receptacles.

– Doug Deden
Jun 5 at 22:16





You refer to "the receptacle in ROOM A". If that's a receptacle (aka female, aka socket), how do you intend to "plug the UPS power out" into it? The UPS output is also via receptacles.

– Doug Deden
Jun 5 at 22:16




17




17





@staticGenerator, good thing you've decided not to use a male-male cord -- those are extremely dangerous, since when either end is plugged in, the exposed prongs on the other end are hot. This could easily kill someone who doesn't realize this cord is "special".

– Nate Strickland
Jun 5 at 23:25





@staticGenerator, good thing you've decided not to use a male-male cord -- those are extremely dangerous, since when either end is plugged in, the exposed prongs on the other end are hot. This could easily kill someone who doesn't realize this cord is "special".

– Nate Strickland
Jun 5 at 23:25




12




12





The male-to-male cord is commonly nicknamed "suicide cord", for the reason Nate has given.

– donjuedo
Jun 6 at 11:39





The male-to-male cord is commonly nicknamed "suicide cord", for the reason Nate has given.

– donjuedo
Jun 6 at 11:39




4




4





Is this an infrastructure sized UPS? Seriously, if it's not a UPS you need a forklift to move then just buy another one for ROOM B. It will cost you more to do what you are planning and you'll be far less likely to kill yourself or others.

– J...
Jun 6 at 12:26





Is this an infrastructure sized UPS? Seriously, if it's not a UPS you need a forklift to move then just buy another one for ROOM B. It will cost you more to do what you are planning and you'll be far less likely to kill yourself or others.

– J...
Jun 6 at 12:26




3




3





@Adonalsium 3000VA is not small (for a house). It's much too big to even run on a standard 15A branch circuit. OP apparently also has a generator and just needs these UPSes to ride through generator startup. For just a desktop computer a little 600VA job would generally be fine and would barely cost more than materials, to say nothing of the work of installing the extension. Don't know about you, here in Canada 30m (ie:100ft) of 14/2 runs almost $60, and that doesn't count boxes and incidentals, drywall mud, paint, etc.

– J...
Jun 6 at 15:29






@Adonalsium 3000VA is not small (for a house). It's much too big to even run on a standard 15A branch circuit. OP apparently also has a generator and just needs these UPSes to ride through generator startup. For just a desktop computer a little 600VA job would generally be fine and would barely cost more than materials, to say nothing of the work of installing the extension. Don't know about you, here in Canada 30m (ie:100ft) of 14/2 runs almost $60, and that doesn't count boxes and incidentals, drywall mud, paint, etc.

– J...
Jun 6 at 15:29











4 Answers
4






active

oldest

votes


















31


















You need an inlet in Room A, not an outlet



enter image description here



You'll need an outlet box with an inlet in it in Room A so that you can plug the output of the UPS into it with a proper cord (read: if you have to do weird crap to your cord to plug the output of the UPS into the wall, stop, because that's a sign you're doing it wrong!). From there, you can use a suitable chapter 3 wiring method (assuming the crawlspace is not wet, NM/Romex will do; use UF aka "outdoor Romex" instead if it is wet/damp, though) to connect the inlet box in Room A to an ordinary box+receptacle in Room B.






share|improve this answer























  • 2





    Thanks, yes my goal was to put a male connector on both ends of the cord (a.k.a. “Weird crap”), but later found receptacles with male connectors that could be used. Unfamiliar with UF cable but I’ll do the research.

    – staticGenerator
    Jun 5 at 23:29






  • 2





    @staticGenerator: think about the kinds of Bad Stuff that could happen if you (or someone else) accidentally used a male<->male cable to plug the UPS output into a live outlet!

    – Peter Cordes
    Jun 6 at 7:13






  • 34





    @staticGenerator In the UK, a power cord with male connectors on both ends is known as a "Jesus cable" - because if you use one, you'll be seeing him soon.

    – Martin Bonner
    Jun 6 at 7:32






  • 12





    @MartinBonner some people call it a suicide cord for similar reasons.

    – ratchet freak
    Jun 6 at 8:00






  • 2





    How not to do it: youtube.com/watch?v=At0advb9_fA

    – Tobias Mädel
    Jun 6 at 13:38


















5


















I have a feeling you will find this to be quite a bit more involved than you originally expected. In addition to whatever other code issues involved in setting up a power "inlet" in Room A (as opposed to the normal receptacle = "outlet"), at a minimum you would need to use approved wiring methods to get from Room A to Room B. That means Romex properly installed - i.e., protected from damage, securely attached, etc. - or wires in conduit. As noted in another answer, regular Romex may not even be an option if the cable actually runs "under" the house as opposed to "through the basement". It means real junction boxes on both ends. It means a lot of work - for relatively little benefit.



My recommendation is "anything else". That includes:



  • If the UPS is relatively small (that's $ and capacity, which basically go together), just get a second UPS for Room B and you're done.


  • If the UPS is relatively large then you could run a heavy duty extension cord. That isn't ideal - extension cords are supposed to be for temporary use. But indoors (at least no problems with weather and wild animals, etc.) and with a heavy duty UL-listed cord - e.g., 12 or even 10 AWG instead of the cheap 14 or 16 AWG that you find in the dollar stores - it would run just fine. But any time you use an extension cord you have to be aware of any possibility of damage - the cables buried inside your walls are safe, the cords outside your walls can be damaged by: kids, pets, furniture (e.g., rolling chairs), doors (I've seen people put extension cords under a door and not think about how it can get into the edge of the door and then get pinched with every open/close), etc. There are reasons extension cords are not supposed to be used for a permanent installation - but it is better than a non-compliant "permanent" installation.






share|improve this answer





















  • 1





    Thanks! The goal was to avoid using an electrical cord. My wife will avoid tripping over it, but I will definitely face plant over it in the middle of the night. The secondary UPS is a fair option, although the main UPS will be plugged into a generator when extensive power outages occur, so being able to have it’s output accessible in the second room would be a real plus. Wish I could afford a more expensive option, but that will have to wait until later...

    – staticGenerator
    Jun 5 at 23:19






  • 9





    @staticGenerator - Have you tested the UPS on the generator? UPS's and small generators often don't work well together. If you've got a 20KVA whole house generator that'll probably work fine, but a small 5KVA "contractor special" generator may not provide a stable enough source for the UPS and it'll keep tripping over to battery. Even small inverter generators tend not to work well (I haven't had much luck with anything smaller than a 6500W inverter generator). Ironically, the auto-ranging power supplies found on most computers is more tolerant and can work even when the UPS doesn't.

    – Johnny
    Jun 6 at 0:54







  • 3





    @Johnny: It's not really "ironic"; the UPS cares about power "quality" (shape of the sine wave) but a computer power supply just rectifies to DC (and converts that to 12VDC with a switching power supply). Unlike an AC motor, it doesn't care much about power quality. Modern power supplies do have power-factor correction so they try to "look" like a resistive load where voltage and current are in phase, instead only drawing current from the voltage peaks of sine waves, but probably they'd still be fine with square wave or DC input. A simple bridge rectifier + capacitor would be.

    – Peter Cordes
    Jun 6 at 7:20






  • 3





    But yeah from the right POV it is ironic that the computer is fine, but the UPS that's supposed to protect the computer from power problems is itself having problems.

    – Peter Cordes
    Jun 6 at 7:22






  • 1





    That's the penultimate solution. The ultimate solution is a DC battery bank in the house, and server gear bought with power supplies that'll accept battery voltage. The battery is topped up by solar, wind, mains, or a generator. Nice thing here is, the room lighting can also be put on this.

    – Harper
    Jun 6 at 23:43


















3


















Yes. You are allowed to use standard practices for in-wall wiring to build a "runt circuit" that goes A to B to C to D and does not actually go to any service panel.



You fit standard outlets in all locations but exactly one. Since there are no other inlets, you fit one inlet capable of taking an extension cord.



Every circuit needs some number of outlets and exactly one inlet. Normally the inlet is direct wiring to the service panel, but not today. If for some reason you want to have 2 possible inlets, you still install one inlet and simply move it as needed.






share|improve this answer





















  • 1





    Would the wiring be required to be at least 12AWG to accommodate the possibility of a heavy-duty extension cord plugged into a 20A outlet?

    – supercat
    Jun 6 at 23:01






  • 1





    @supercat good point, I don't think Code actually calls that one out, but it's a good idea since NEMA 5-15 inlets will fit 5-20 cords.

    – Harper
    Jun 6 at 23:40


















1


















To use a UPS located in one room for equipment located in another room, you need a UPS designed to be hardwired.



This is called a Structured Wiring UPS, and they are typically prohibitively expensive. They have internal wiring connections that an electrician would connect circuit breakers and then outlets to. They do not have normal outlets on them that you're used to seeing on a UPS.



An extension cord plugged into a normal UPS is the most you can do, and even that is against code if it's always going to be connected that way instead of just temporarily.



Putting outlets in the wall and connecting them to a normal UPS is not allowed as far a I know.






share|improve this answer























  • 6





    Citation needed on not being allowed to construct your own extension cords and wire outlets -- this definitely isn't true everywhere in the world.

    – Nate Strickland
    Jun 5 at 22:49











  • @NateStrickland I think you're right that it's allowed to make your own extension cords, I thought it was a NEC thing but it's just dumb OSHA guidelines which don't really apply here.

    – Dotes
    Jun 5 at 22:58







  • 5





    @Dotes -- can you give an OSHA or NEC cite on it being forbidden to have an inlet/outlet pair that's powered up by a cord-and-plug connection to a UPS?

    – ThreePhaseEel
    Jun 6 at 1:46











  • This is only needed on very long distances. On just a few meters, wiring everything yourself is perfectly fine.

    – Overmind
    Jun 7 at 7:55












Your Answer








StackExchange.ready(function()
var channelOptions =
tags: "".split(" "),
id: "73"
;
initTagRenderer("".split(" "), "".split(" "), channelOptions);

StackExchange.using("externalEditor", function()
// Have to fire editor after snippets, if snippets enabled
if (StackExchange.settings.snippets.snippetsEnabled)
StackExchange.using("snippets", function()
createEditor();
);

else
createEditor();

);

function createEditor()
StackExchange.prepareEditor(
heartbeatType: 'answer',
autoActivateHeartbeat: false,
convertImagesToLinks: false,
noModals: true,
showLowRepImageUploadWarning: true,
reputationToPostImages: null,
bindNavPrevention: true,
postfix: "",
imageUploader:
brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/4.0/"u003ecc by-sa 4.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
allowUrls: true
,
noCode: true, onDemand: true,
discardSelector: ".discard-answer"
,immediatelyShowMarkdownHelp:true
);



);














draft saved

draft discarded
















StackExchange.ready(
function ()
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdiy.stackexchange.com%2fquestions%2f166657%2fgetting-ups-power-from-one-room-to-another%23new-answer', 'question_page');

);

Post as a guest















Required, but never shown


























4 Answers
4






active

oldest

votes








4 Answers
4






active

oldest

votes









active

oldest

votes






active

oldest

votes









31


















You need an inlet in Room A, not an outlet



enter image description here



You'll need an outlet box with an inlet in it in Room A so that you can plug the output of the UPS into it with a proper cord (read: if you have to do weird crap to your cord to plug the output of the UPS into the wall, stop, because that's a sign you're doing it wrong!). From there, you can use a suitable chapter 3 wiring method (assuming the crawlspace is not wet, NM/Romex will do; use UF aka "outdoor Romex" instead if it is wet/damp, though) to connect the inlet box in Room A to an ordinary box+receptacle in Room B.






share|improve this answer























  • 2





    Thanks, yes my goal was to put a male connector on both ends of the cord (a.k.a. “Weird crap”), but later found receptacles with male connectors that could be used. Unfamiliar with UF cable but I’ll do the research.

    – staticGenerator
    Jun 5 at 23:29






  • 2





    @staticGenerator: think about the kinds of Bad Stuff that could happen if you (or someone else) accidentally used a male<->male cable to plug the UPS output into a live outlet!

    – Peter Cordes
    Jun 6 at 7:13






  • 34





    @staticGenerator In the UK, a power cord with male connectors on both ends is known as a "Jesus cable" - because if you use one, you'll be seeing him soon.

    – Martin Bonner
    Jun 6 at 7:32






  • 12





    @MartinBonner some people call it a suicide cord for similar reasons.

    – ratchet freak
    Jun 6 at 8:00






  • 2





    How not to do it: youtube.com/watch?v=At0advb9_fA

    – Tobias Mädel
    Jun 6 at 13:38















31


















You need an inlet in Room A, not an outlet



enter image description here



You'll need an outlet box with an inlet in it in Room A so that you can plug the output of the UPS into it with a proper cord (read: if you have to do weird crap to your cord to plug the output of the UPS into the wall, stop, because that's a sign you're doing it wrong!). From there, you can use a suitable chapter 3 wiring method (assuming the crawlspace is not wet, NM/Romex will do; use UF aka "outdoor Romex" instead if it is wet/damp, though) to connect the inlet box in Room A to an ordinary box+receptacle in Room B.






share|improve this answer























  • 2





    Thanks, yes my goal was to put a male connector on both ends of the cord (a.k.a. “Weird crap”), but later found receptacles with male connectors that could be used. Unfamiliar with UF cable but I’ll do the research.

    – staticGenerator
    Jun 5 at 23:29






  • 2





    @staticGenerator: think about the kinds of Bad Stuff that could happen if you (or someone else) accidentally used a male<->male cable to plug the UPS output into a live outlet!

    – Peter Cordes
    Jun 6 at 7:13






  • 34





    @staticGenerator In the UK, a power cord with male connectors on both ends is known as a "Jesus cable" - because if you use one, you'll be seeing him soon.

    – Martin Bonner
    Jun 6 at 7:32






  • 12





    @MartinBonner some people call it a suicide cord for similar reasons.

    – ratchet freak
    Jun 6 at 8:00






  • 2





    How not to do it: youtube.com/watch?v=At0advb9_fA

    – Tobias Mädel
    Jun 6 at 13:38













31














31










31









You need an inlet in Room A, not an outlet



enter image description here



You'll need an outlet box with an inlet in it in Room A so that you can plug the output of the UPS into it with a proper cord (read: if you have to do weird crap to your cord to plug the output of the UPS into the wall, stop, because that's a sign you're doing it wrong!). From there, you can use a suitable chapter 3 wiring method (assuming the crawlspace is not wet, NM/Romex will do; use UF aka "outdoor Romex" instead if it is wet/damp, though) to connect the inlet box in Room A to an ordinary box+receptacle in Room B.






share|improve this answer
















You need an inlet in Room A, not an outlet



enter image description here



You'll need an outlet box with an inlet in it in Room A so that you can plug the output of the UPS into it with a proper cord (read: if you have to do weird crap to your cord to plug the output of the UPS into the wall, stop, because that's a sign you're doing it wrong!). From there, you can use a suitable chapter 3 wiring method (assuming the crawlspace is not wet, NM/Romex will do; use UF aka "outdoor Romex" instead if it is wet/damp, though) to connect the inlet box in Room A to an ordinary box+receptacle in Room B.







share|improve this answer















share|improve this answer




share|improve this answer








edited Jun 6 at 4:41









Harper

103k7 gold badges76 silver badges221 bronze badges




103k7 gold badges76 silver badges221 bronze badges










answered Jun 5 at 22:36









ThreePhaseEelThreePhaseEel

37.5k11 gold badges58 silver badges113 bronze badges




37.5k11 gold badges58 silver badges113 bronze badges










  • 2





    Thanks, yes my goal was to put a male connector on both ends of the cord (a.k.a. “Weird crap”), but later found receptacles with male connectors that could be used. Unfamiliar with UF cable but I’ll do the research.

    – staticGenerator
    Jun 5 at 23:29






  • 2





    @staticGenerator: think about the kinds of Bad Stuff that could happen if you (or someone else) accidentally used a male<->male cable to plug the UPS output into a live outlet!

    – Peter Cordes
    Jun 6 at 7:13






  • 34





    @staticGenerator In the UK, a power cord with male connectors on both ends is known as a "Jesus cable" - because if you use one, you'll be seeing him soon.

    – Martin Bonner
    Jun 6 at 7:32






  • 12





    @MartinBonner some people call it a suicide cord for similar reasons.

    – ratchet freak
    Jun 6 at 8:00






  • 2





    How not to do it: youtube.com/watch?v=At0advb9_fA

    – Tobias Mädel
    Jun 6 at 13:38












  • 2





    Thanks, yes my goal was to put a male connector on both ends of the cord (a.k.a. “Weird crap”), but later found receptacles with male connectors that could be used. Unfamiliar with UF cable but I’ll do the research.

    – staticGenerator
    Jun 5 at 23:29






  • 2





    @staticGenerator: think about the kinds of Bad Stuff that could happen if you (or someone else) accidentally used a male<->male cable to plug the UPS output into a live outlet!

    – Peter Cordes
    Jun 6 at 7:13






  • 34





    @staticGenerator In the UK, a power cord with male connectors on both ends is known as a "Jesus cable" - because if you use one, you'll be seeing him soon.

    – Martin Bonner
    Jun 6 at 7:32






  • 12





    @MartinBonner some people call it a suicide cord for similar reasons.

    – ratchet freak
    Jun 6 at 8:00






  • 2





    How not to do it: youtube.com/watch?v=At0advb9_fA

    – Tobias Mädel
    Jun 6 at 13:38







2




2





Thanks, yes my goal was to put a male connector on both ends of the cord (a.k.a. “Weird crap”), but later found receptacles with male connectors that could be used. Unfamiliar with UF cable but I’ll do the research.

– staticGenerator
Jun 5 at 23:29





Thanks, yes my goal was to put a male connector on both ends of the cord (a.k.a. “Weird crap”), but later found receptacles with male connectors that could be used. Unfamiliar with UF cable but I’ll do the research.

– staticGenerator
Jun 5 at 23:29




2




2





@staticGenerator: think about the kinds of Bad Stuff that could happen if you (or someone else) accidentally used a male<->male cable to plug the UPS output into a live outlet!

– Peter Cordes
Jun 6 at 7:13





@staticGenerator: think about the kinds of Bad Stuff that could happen if you (or someone else) accidentally used a male<->male cable to plug the UPS output into a live outlet!

– Peter Cordes
Jun 6 at 7:13




34




34





@staticGenerator In the UK, a power cord with male connectors on both ends is known as a "Jesus cable" - because if you use one, you'll be seeing him soon.

– Martin Bonner
Jun 6 at 7:32





@staticGenerator In the UK, a power cord with male connectors on both ends is known as a "Jesus cable" - because if you use one, you'll be seeing him soon.

– Martin Bonner
Jun 6 at 7:32




12




12





@MartinBonner some people call it a suicide cord for similar reasons.

– ratchet freak
Jun 6 at 8:00





@MartinBonner some people call it a suicide cord for similar reasons.

– ratchet freak
Jun 6 at 8:00




2




2





How not to do it: youtube.com/watch?v=At0advb9_fA

– Tobias Mädel
Jun 6 at 13:38





How not to do it: youtube.com/watch?v=At0advb9_fA

– Tobias Mädel
Jun 6 at 13:38













5


















I have a feeling you will find this to be quite a bit more involved than you originally expected. In addition to whatever other code issues involved in setting up a power "inlet" in Room A (as opposed to the normal receptacle = "outlet"), at a minimum you would need to use approved wiring methods to get from Room A to Room B. That means Romex properly installed - i.e., protected from damage, securely attached, etc. - or wires in conduit. As noted in another answer, regular Romex may not even be an option if the cable actually runs "under" the house as opposed to "through the basement". It means real junction boxes on both ends. It means a lot of work - for relatively little benefit.



My recommendation is "anything else". That includes:



  • If the UPS is relatively small (that's $ and capacity, which basically go together), just get a second UPS for Room B and you're done.


  • If the UPS is relatively large then you could run a heavy duty extension cord. That isn't ideal - extension cords are supposed to be for temporary use. But indoors (at least no problems with weather and wild animals, etc.) and with a heavy duty UL-listed cord - e.g., 12 or even 10 AWG instead of the cheap 14 or 16 AWG that you find in the dollar stores - it would run just fine. But any time you use an extension cord you have to be aware of any possibility of damage - the cables buried inside your walls are safe, the cords outside your walls can be damaged by: kids, pets, furniture (e.g., rolling chairs), doors (I've seen people put extension cords under a door and not think about how it can get into the edge of the door and then get pinched with every open/close), etc. There are reasons extension cords are not supposed to be used for a permanent installation - but it is better than a non-compliant "permanent" installation.






share|improve this answer





















  • 1





    Thanks! The goal was to avoid using an electrical cord. My wife will avoid tripping over it, but I will definitely face plant over it in the middle of the night. The secondary UPS is a fair option, although the main UPS will be plugged into a generator when extensive power outages occur, so being able to have it’s output accessible in the second room would be a real plus. Wish I could afford a more expensive option, but that will have to wait until later...

    – staticGenerator
    Jun 5 at 23:19






  • 9





    @staticGenerator - Have you tested the UPS on the generator? UPS's and small generators often don't work well together. If you've got a 20KVA whole house generator that'll probably work fine, but a small 5KVA "contractor special" generator may not provide a stable enough source for the UPS and it'll keep tripping over to battery. Even small inverter generators tend not to work well (I haven't had much luck with anything smaller than a 6500W inverter generator). Ironically, the auto-ranging power supplies found on most computers is more tolerant and can work even when the UPS doesn't.

    – Johnny
    Jun 6 at 0:54







  • 3





    @Johnny: It's not really "ironic"; the UPS cares about power "quality" (shape of the sine wave) but a computer power supply just rectifies to DC (and converts that to 12VDC with a switching power supply). Unlike an AC motor, it doesn't care much about power quality. Modern power supplies do have power-factor correction so they try to "look" like a resistive load where voltage and current are in phase, instead only drawing current from the voltage peaks of sine waves, but probably they'd still be fine with square wave or DC input. A simple bridge rectifier + capacitor would be.

    – Peter Cordes
    Jun 6 at 7:20






  • 3





    But yeah from the right POV it is ironic that the computer is fine, but the UPS that's supposed to protect the computer from power problems is itself having problems.

    – Peter Cordes
    Jun 6 at 7:22






  • 1





    That's the penultimate solution. The ultimate solution is a DC battery bank in the house, and server gear bought with power supplies that'll accept battery voltage. The battery is topped up by solar, wind, mains, or a generator. Nice thing here is, the room lighting can also be put on this.

    – Harper
    Jun 6 at 23:43















5


















I have a feeling you will find this to be quite a bit more involved than you originally expected. In addition to whatever other code issues involved in setting up a power "inlet" in Room A (as opposed to the normal receptacle = "outlet"), at a minimum you would need to use approved wiring methods to get from Room A to Room B. That means Romex properly installed - i.e., protected from damage, securely attached, etc. - or wires in conduit. As noted in another answer, regular Romex may not even be an option if the cable actually runs "under" the house as opposed to "through the basement". It means real junction boxes on both ends. It means a lot of work - for relatively little benefit.



My recommendation is "anything else". That includes:



  • If the UPS is relatively small (that's $ and capacity, which basically go together), just get a second UPS for Room B and you're done.


  • If the UPS is relatively large then you could run a heavy duty extension cord. That isn't ideal - extension cords are supposed to be for temporary use. But indoors (at least no problems with weather and wild animals, etc.) and with a heavy duty UL-listed cord - e.g., 12 or even 10 AWG instead of the cheap 14 or 16 AWG that you find in the dollar stores - it would run just fine. But any time you use an extension cord you have to be aware of any possibility of damage - the cables buried inside your walls are safe, the cords outside your walls can be damaged by: kids, pets, furniture (e.g., rolling chairs), doors (I've seen people put extension cords under a door and not think about how it can get into the edge of the door and then get pinched with every open/close), etc. There are reasons extension cords are not supposed to be used for a permanent installation - but it is better than a non-compliant "permanent" installation.






share|improve this answer





















  • 1





    Thanks! The goal was to avoid using an electrical cord. My wife will avoid tripping over it, but I will definitely face plant over it in the middle of the night. The secondary UPS is a fair option, although the main UPS will be plugged into a generator when extensive power outages occur, so being able to have it’s output accessible in the second room would be a real plus. Wish I could afford a more expensive option, but that will have to wait until later...

    – staticGenerator
    Jun 5 at 23:19






  • 9





    @staticGenerator - Have you tested the UPS on the generator? UPS's and small generators often don't work well together. If you've got a 20KVA whole house generator that'll probably work fine, but a small 5KVA "contractor special" generator may not provide a stable enough source for the UPS and it'll keep tripping over to battery. Even small inverter generators tend not to work well (I haven't had much luck with anything smaller than a 6500W inverter generator). Ironically, the auto-ranging power supplies found on most computers is more tolerant and can work even when the UPS doesn't.

    – Johnny
    Jun 6 at 0:54







  • 3





    @Johnny: It's not really "ironic"; the UPS cares about power "quality" (shape of the sine wave) but a computer power supply just rectifies to DC (and converts that to 12VDC with a switching power supply). Unlike an AC motor, it doesn't care much about power quality. Modern power supplies do have power-factor correction so they try to "look" like a resistive load where voltage and current are in phase, instead only drawing current from the voltage peaks of sine waves, but probably they'd still be fine with square wave or DC input. A simple bridge rectifier + capacitor would be.

    – Peter Cordes
    Jun 6 at 7:20






  • 3





    But yeah from the right POV it is ironic that the computer is fine, but the UPS that's supposed to protect the computer from power problems is itself having problems.

    – Peter Cordes
    Jun 6 at 7:22






  • 1





    That's the penultimate solution. The ultimate solution is a DC battery bank in the house, and server gear bought with power supplies that'll accept battery voltage. The battery is topped up by solar, wind, mains, or a generator. Nice thing here is, the room lighting can also be put on this.

    – Harper
    Jun 6 at 23:43













5














5










5









I have a feeling you will find this to be quite a bit more involved than you originally expected. In addition to whatever other code issues involved in setting up a power "inlet" in Room A (as opposed to the normal receptacle = "outlet"), at a minimum you would need to use approved wiring methods to get from Room A to Room B. That means Romex properly installed - i.e., protected from damage, securely attached, etc. - or wires in conduit. As noted in another answer, regular Romex may not even be an option if the cable actually runs "under" the house as opposed to "through the basement". It means real junction boxes on both ends. It means a lot of work - for relatively little benefit.



My recommendation is "anything else". That includes:



  • If the UPS is relatively small (that's $ and capacity, which basically go together), just get a second UPS for Room B and you're done.


  • If the UPS is relatively large then you could run a heavy duty extension cord. That isn't ideal - extension cords are supposed to be for temporary use. But indoors (at least no problems with weather and wild animals, etc.) and with a heavy duty UL-listed cord - e.g., 12 or even 10 AWG instead of the cheap 14 or 16 AWG that you find in the dollar stores - it would run just fine. But any time you use an extension cord you have to be aware of any possibility of damage - the cables buried inside your walls are safe, the cords outside your walls can be damaged by: kids, pets, furniture (e.g., rolling chairs), doors (I've seen people put extension cords under a door and not think about how it can get into the edge of the door and then get pinched with every open/close), etc. There are reasons extension cords are not supposed to be used for a permanent installation - but it is better than a non-compliant "permanent" installation.






share|improve this answer














I have a feeling you will find this to be quite a bit more involved than you originally expected. In addition to whatever other code issues involved in setting up a power "inlet" in Room A (as opposed to the normal receptacle = "outlet"), at a minimum you would need to use approved wiring methods to get from Room A to Room B. That means Romex properly installed - i.e., protected from damage, securely attached, etc. - or wires in conduit. As noted in another answer, regular Romex may not even be an option if the cable actually runs "under" the house as opposed to "through the basement". It means real junction boxes on both ends. It means a lot of work - for relatively little benefit.



My recommendation is "anything else". That includes:



  • If the UPS is relatively small (that's $ and capacity, which basically go together), just get a second UPS for Room B and you're done.


  • If the UPS is relatively large then you could run a heavy duty extension cord. That isn't ideal - extension cords are supposed to be for temporary use. But indoors (at least no problems with weather and wild animals, etc.) and with a heavy duty UL-listed cord - e.g., 12 or even 10 AWG instead of the cheap 14 or 16 AWG that you find in the dollar stores - it would run just fine. But any time you use an extension cord you have to be aware of any possibility of damage - the cables buried inside your walls are safe, the cords outside your walls can be damaged by: kids, pets, furniture (e.g., rolling chairs), doors (I've seen people put extension cords under a door and not think about how it can get into the edge of the door and then get pinched with every open/close), etc. There are reasons extension cords are not supposed to be used for a permanent installation - but it is better than a non-compliant "permanent" installation.







share|improve this answer













share|improve this answer




share|improve this answer










answered Jun 5 at 22:44









manassehkatzmanassehkatz

18.9k1 gold badge25 silver badges58 bronze badges




18.9k1 gold badge25 silver badges58 bronze badges










  • 1





    Thanks! The goal was to avoid using an electrical cord. My wife will avoid tripping over it, but I will definitely face plant over it in the middle of the night. The secondary UPS is a fair option, although the main UPS will be plugged into a generator when extensive power outages occur, so being able to have it’s output accessible in the second room would be a real plus. Wish I could afford a more expensive option, but that will have to wait until later...

    – staticGenerator
    Jun 5 at 23:19






  • 9





    @staticGenerator - Have you tested the UPS on the generator? UPS's and small generators often don't work well together. If you've got a 20KVA whole house generator that'll probably work fine, but a small 5KVA "contractor special" generator may not provide a stable enough source for the UPS and it'll keep tripping over to battery. Even small inverter generators tend not to work well (I haven't had much luck with anything smaller than a 6500W inverter generator). Ironically, the auto-ranging power supplies found on most computers is more tolerant and can work even when the UPS doesn't.

    – Johnny
    Jun 6 at 0:54







  • 3





    @Johnny: It's not really "ironic"; the UPS cares about power "quality" (shape of the sine wave) but a computer power supply just rectifies to DC (and converts that to 12VDC with a switching power supply). Unlike an AC motor, it doesn't care much about power quality. Modern power supplies do have power-factor correction so they try to "look" like a resistive load where voltage and current are in phase, instead only drawing current from the voltage peaks of sine waves, but probably they'd still be fine with square wave or DC input. A simple bridge rectifier + capacitor would be.

    – Peter Cordes
    Jun 6 at 7:20






  • 3





    But yeah from the right POV it is ironic that the computer is fine, but the UPS that's supposed to protect the computer from power problems is itself having problems.

    – Peter Cordes
    Jun 6 at 7:22






  • 1





    That's the penultimate solution. The ultimate solution is a DC battery bank in the house, and server gear bought with power supplies that'll accept battery voltage. The battery is topped up by solar, wind, mains, or a generator. Nice thing here is, the room lighting can also be put on this.

    – Harper
    Jun 6 at 23:43












  • 1





    Thanks! The goal was to avoid using an electrical cord. My wife will avoid tripping over it, but I will definitely face plant over it in the middle of the night. The secondary UPS is a fair option, although the main UPS will be plugged into a generator when extensive power outages occur, so being able to have it’s output accessible in the second room would be a real plus. Wish I could afford a more expensive option, but that will have to wait until later...

    – staticGenerator
    Jun 5 at 23:19






  • 9





    @staticGenerator - Have you tested the UPS on the generator? UPS's and small generators often don't work well together. If you've got a 20KVA whole house generator that'll probably work fine, but a small 5KVA "contractor special" generator may not provide a stable enough source for the UPS and it'll keep tripping over to battery. Even small inverter generators tend not to work well (I haven't had much luck with anything smaller than a 6500W inverter generator). Ironically, the auto-ranging power supplies found on most computers is more tolerant and can work even when the UPS doesn't.

    – Johnny
    Jun 6 at 0:54







  • 3





    @Johnny: It's not really "ironic"; the UPS cares about power "quality" (shape of the sine wave) but a computer power supply just rectifies to DC (and converts that to 12VDC with a switching power supply). Unlike an AC motor, it doesn't care much about power quality. Modern power supplies do have power-factor correction so they try to "look" like a resistive load where voltage and current are in phase, instead only drawing current from the voltage peaks of sine waves, but probably they'd still be fine with square wave or DC input. A simple bridge rectifier + capacitor would be.

    – Peter Cordes
    Jun 6 at 7:20






  • 3





    But yeah from the right POV it is ironic that the computer is fine, but the UPS that's supposed to protect the computer from power problems is itself having problems.

    – Peter Cordes
    Jun 6 at 7:22






  • 1





    That's the penultimate solution. The ultimate solution is a DC battery bank in the house, and server gear bought with power supplies that'll accept battery voltage. The battery is topped up by solar, wind, mains, or a generator. Nice thing here is, the room lighting can also be put on this.

    – Harper
    Jun 6 at 23:43







1




1





Thanks! The goal was to avoid using an electrical cord. My wife will avoid tripping over it, but I will definitely face plant over it in the middle of the night. The secondary UPS is a fair option, although the main UPS will be plugged into a generator when extensive power outages occur, so being able to have it’s output accessible in the second room would be a real plus. Wish I could afford a more expensive option, but that will have to wait until later...

– staticGenerator
Jun 5 at 23:19





Thanks! The goal was to avoid using an electrical cord. My wife will avoid tripping over it, but I will definitely face plant over it in the middle of the night. The secondary UPS is a fair option, although the main UPS will be plugged into a generator when extensive power outages occur, so being able to have it’s output accessible in the second room would be a real plus. Wish I could afford a more expensive option, but that will have to wait until later...

– staticGenerator
Jun 5 at 23:19




9




9





@staticGenerator - Have you tested the UPS on the generator? UPS's and small generators often don't work well together. If you've got a 20KVA whole house generator that'll probably work fine, but a small 5KVA "contractor special" generator may not provide a stable enough source for the UPS and it'll keep tripping over to battery. Even small inverter generators tend not to work well (I haven't had much luck with anything smaller than a 6500W inverter generator). Ironically, the auto-ranging power supplies found on most computers is more tolerant and can work even when the UPS doesn't.

– Johnny
Jun 6 at 0:54






@staticGenerator - Have you tested the UPS on the generator? UPS's and small generators often don't work well together. If you've got a 20KVA whole house generator that'll probably work fine, but a small 5KVA "contractor special" generator may not provide a stable enough source for the UPS and it'll keep tripping over to battery. Even small inverter generators tend not to work well (I haven't had much luck with anything smaller than a 6500W inverter generator). Ironically, the auto-ranging power supplies found on most computers is more tolerant and can work even when the UPS doesn't.

– Johnny
Jun 6 at 0:54





3




3





@Johnny: It's not really "ironic"; the UPS cares about power "quality" (shape of the sine wave) but a computer power supply just rectifies to DC (and converts that to 12VDC with a switching power supply). Unlike an AC motor, it doesn't care much about power quality. Modern power supplies do have power-factor correction so they try to "look" like a resistive load where voltage and current are in phase, instead only drawing current from the voltage peaks of sine waves, but probably they'd still be fine with square wave or DC input. A simple bridge rectifier + capacitor would be.

– Peter Cordes
Jun 6 at 7:20





@Johnny: It's not really "ironic"; the UPS cares about power "quality" (shape of the sine wave) but a computer power supply just rectifies to DC (and converts that to 12VDC with a switching power supply). Unlike an AC motor, it doesn't care much about power quality. Modern power supplies do have power-factor correction so they try to "look" like a resistive load where voltage and current are in phase, instead only drawing current from the voltage peaks of sine waves, but probably they'd still be fine with square wave or DC input. A simple bridge rectifier + capacitor would be.

– Peter Cordes
Jun 6 at 7:20




3




3





But yeah from the right POV it is ironic that the computer is fine, but the UPS that's supposed to protect the computer from power problems is itself having problems.

– Peter Cordes
Jun 6 at 7:22





But yeah from the right POV it is ironic that the computer is fine, but the UPS that's supposed to protect the computer from power problems is itself having problems.

– Peter Cordes
Jun 6 at 7:22




1




1





That's the penultimate solution. The ultimate solution is a DC battery bank in the house, and server gear bought with power supplies that'll accept battery voltage. The battery is topped up by solar, wind, mains, or a generator. Nice thing here is, the room lighting can also be put on this.

– Harper
Jun 6 at 23:43





That's the penultimate solution. The ultimate solution is a DC battery bank in the house, and server gear bought with power supplies that'll accept battery voltage. The battery is topped up by solar, wind, mains, or a generator. Nice thing here is, the room lighting can also be put on this.

– Harper
Jun 6 at 23:43











3


















Yes. You are allowed to use standard practices for in-wall wiring to build a "runt circuit" that goes A to B to C to D and does not actually go to any service panel.



You fit standard outlets in all locations but exactly one. Since there are no other inlets, you fit one inlet capable of taking an extension cord.



Every circuit needs some number of outlets and exactly one inlet. Normally the inlet is direct wiring to the service panel, but not today. If for some reason you want to have 2 possible inlets, you still install one inlet and simply move it as needed.






share|improve this answer





















  • 1





    Would the wiring be required to be at least 12AWG to accommodate the possibility of a heavy-duty extension cord plugged into a 20A outlet?

    – supercat
    Jun 6 at 23:01






  • 1





    @supercat good point, I don't think Code actually calls that one out, but it's a good idea since NEMA 5-15 inlets will fit 5-20 cords.

    – Harper
    Jun 6 at 23:40















3


















Yes. You are allowed to use standard practices for in-wall wiring to build a "runt circuit" that goes A to B to C to D and does not actually go to any service panel.



You fit standard outlets in all locations but exactly one. Since there are no other inlets, you fit one inlet capable of taking an extension cord.



Every circuit needs some number of outlets and exactly one inlet. Normally the inlet is direct wiring to the service panel, but not today. If for some reason you want to have 2 possible inlets, you still install one inlet and simply move it as needed.






share|improve this answer





















  • 1





    Would the wiring be required to be at least 12AWG to accommodate the possibility of a heavy-duty extension cord plugged into a 20A outlet?

    – supercat
    Jun 6 at 23:01






  • 1





    @supercat good point, I don't think Code actually calls that one out, but it's a good idea since NEMA 5-15 inlets will fit 5-20 cords.

    – Harper
    Jun 6 at 23:40













3














3










3









Yes. You are allowed to use standard practices for in-wall wiring to build a "runt circuit" that goes A to B to C to D and does not actually go to any service panel.



You fit standard outlets in all locations but exactly one. Since there are no other inlets, you fit one inlet capable of taking an extension cord.



Every circuit needs some number of outlets and exactly one inlet. Normally the inlet is direct wiring to the service panel, but not today. If for some reason you want to have 2 possible inlets, you still install one inlet and simply move it as needed.






share|improve this answer














Yes. You are allowed to use standard practices for in-wall wiring to build a "runt circuit" that goes A to B to C to D and does not actually go to any service panel.



You fit standard outlets in all locations but exactly one. Since there are no other inlets, you fit one inlet capable of taking an extension cord.



Every circuit needs some number of outlets and exactly one inlet. Normally the inlet is direct wiring to the service panel, but not today. If for some reason you want to have 2 possible inlets, you still install one inlet and simply move it as needed.







share|improve this answer













share|improve this answer




share|improve this answer










answered Jun 6 at 16:33









HarperHarper

103k7 gold badges76 silver badges221 bronze badges




103k7 gold badges76 silver badges221 bronze badges










  • 1





    Would the wiring be required to be at least 12AWG to accommodate the possibility of a heavy-duty extension cord plugged into a 20A outlet?

    – supercat
    Jun 6 at 23:01






  • 1





    @supercat good point, I don't think Code actually calls that one out, but it's a good idea since NEMA 5-15 inlets will fit 5-20 cords.

    – Harper
    Jun 6 at 23:40












  • 1





    Would the wiring be required to be at least 12AWG to accommodate the possibility of a heavy-duty extension cord plugged into a 20A outlet?

    – supercat
    Jun 6 at 23:01






  • 1





    @supercat good point, I don't think Code actually calls that one out, but it's a good idea since NEMA 5-15 inlets will fit 5-20 cords.

    – Harper
    Jun 6 at 23:40







1




1





Would the wiring be required to be at least 12AWG to accommodate the possibility of a heavy-duty extension cord plugged into a 20A outlet?

– supercat
Jun 6 at 23:01





Would the wiring be required to be at least 12AWG to accommodate the possibility of a heavy-duty extension cord plugged into a 20A outlet?

– supercat
Jun 6 at 23:01




1




1





@supercat good point, I don't think Code actually calls that one out, but it's a good idea since NEMA 5-15 inlets will fit 5-20 cords.

– Harper
Jun 6 at 23:40





@supercat good point, I don't think Code actually calls that one out, but it's a good idea since NEMA 5-15 inlets will fit 5-20 cords.

– Harper
Jun 6 at 23:40











1


















To use a UPS located in one room for equipment located in another room, you need a UPS designed to be hardwired.



This is called a Structured Wiring UPS, and they are typically prohibitively expensive. They have internal wiring connections that an electrician would connect circuit breakers and then outlets to. They do not have normal outlets on them that you're used to seeing on a UPS.



An extension cord plugged into a normal UPS is the most you can do, and even that is against code if it's always going to be connected that way instead of just temporarily.



Putting outlets in the wall and connecting them to a normal UPS is not allowed as far a I know.






share|improve this answer























  • 6





    Citation needed on not being allowed to construct your own extension cords and wire outlets -- this definitely isn't true everywhere in the world.

    – Nate Strickland
    Jun 5 at 22:49











  • @NateStrickland I think you're right that it's allowed to make your own extension cords, I thought it was a NEC thing but it's just dumb OSHA guidelines which don't really apply here.

    – Dotes
    Jun 5 at 22:58







  • 5





    @Dotes -- can you give an OSHA or NEC cite on it being forbidden to have an inlet/outlet pair that's powered up by a cord-and-plug connection to a UPS?

    – ThreePhaseEel
    Jun 6 at 1:46











  • This is only needed on very long distances. On just a few meters, wiring everything yourself is perfectly fine.

    – Overmind
    Jun 7 at 7:55















1


















To use a UPS located in one room for equipment located in another room, you need a UPS designed to be hardwired.



This is called a Structured Wiring UPS, and they are typically prohibitively expensive. They have internal wiring connections that an electrician would connect circuit breakers and then outlets to. They do not have normal outlets on them that you're used to seeing on a UPS.



An extension cord plugged into a normal UPS is the most you can do, and even that is against code if it's always going to be connected that way instead of just temporarily.



Putting outlets in the wall and connecting them to a normal UPS is not allowed as far a I know.






share|improve this answer























  • 6





    Citation needed on not being allowed to construct your own extension cords and wire outlets -- this definitely isn't true everywhere in the world.

    – Nate Strickland
    Jun 5 at 22:49











  • @NateStrickland I think you're right that it's allowed to make your own extension cords, I thought it was a NEC thing but it's just dumb OSHA guidelines which don't really apply here.

    – Dotes
    Jun 5 at 22:58







  • 5





    @Dotes -- can you give an OSHA or NEC cite on it being forbidden to have an inlet/outlet pair that's powered up by a cord-and-plug connection to a UPS?

    – ThreePhaseEel
    Jun 6 at 1:46











  • This is only needed on very long distances. On just a few meters, wiring everything yourself is perfectly fine.

    – Overmind
    Jun 7 at 7:55













1














1










1









To use a UPS located in one room for equipment located in another room, you need a UPS designed to be hardwired.



This is called a Structured Wiring UPS, and they are typically prohibitively expensive. They have internal wiring connections that an electrician would connect circuit breakers and then outlets to. They do not have normal outlets on them that you're used to seeing on a UPS.



An extension cord plugged into a normal UPS is the most you can do, and even that is against code if it's always going to be connected that way instead of just temporarily.



Putting outlets in the wall and connecting them to a normal UPS is not allowed as far a I know.






share|improve this answer
















To use a UPS located in one room for equipment located in another room, you need a UPS designed to be hardwired.



This is called a Structured Wiring UPS, and they are typically prohibitively expensive. They have internal wiring connections that an electrician would connect circuit breakers and then outlets to. They do not have normal outlets on them that you're used to seeing on a UPS.



An extension cord plugged into a normal UPS is the most you can do, and even that is against code if it's always going to be connected that way instead of just temporarily.



Putting outlets in the wall and connecting them to a normal UPS is not allowed as far a I know.







share|improve this answer















share|improve this answer




share|improve this answer








edited Jun 5 at 22:58

























answered Jun 5 at 22:37









DotesDotes

4,2146 silver badges16 bronze badges




4,2146 silver badges16 bronze badges










  • 6





    Citation needed on not being allowed to construct your own extension cords and wire outlets -- this definitely isn't true everywhere in the world.

    – Nate Strickland
    Jun 5 at 22:49











  • @NateStrickland I think you're right that it's allowed to make your own extension cords, I thought it was a NEC thing but it's just dumb OSHA guidelines which don't really apply here.

    – Dotes
    Jun 5 at 22:58







  • 5





    @Dotes -- can you give an OSHA or NEC cite on it being forbidden to have an inlet/outlet pair that's powered up by a cord-and-plug connection to a UPS?

    – ThreePhaseEel
    Jun 6 at 1:46











  • This is only needed on very long distances. On just a few meters, wiring everything yourself is perfectly fine.

    – Overmind
    Jun 7 at 7:55












  • 6





    Citation needed on not being allowed to construct your own extension cords and wire outlets -- this definitely isn't true everywhere in the world.

    – Nate Strickland
    Jun 5 at 22:49











  • @NateStrickland I think you're right that it's allowed to make your own extension cords, I thought it was a NEC thing but it's just dumb OSHA guidelines which don't really apply here.

    – Dotes
    Jun 5 at 22:58







  • 5





    @Dotes -- can you give an OSHA or NEC cite on it being forbidden to have an inlet/outlet pair that's powered up by a cord-and-plug connection to a UPS?

    – ThreePhaseEel
    Jun 6 at 1:46











  • This is only needed on very long distances. On just a few meters, wiring everything yourself is perfectly fine.

    – Overmind
    Jun 7 at 7:55







6




6





Citation needed on not being allowed to construct your own extension cords and wire outlets -- this definitely isn't true everywhere in the world.

– Nate Strickland
Jun 5 at 22:49





Citation needed on not being allowed to construct your own extension cords and wire outlets -- this definitely isn't true everywhere in the world.

– Nate Strickland
Jun 5 at 22:49













@NateStrickland I think you're right that it's allowed to make your own extension cords, I thought it was a NEC thing but it's just dumb OSHA guidelines which don't really apply here.

– Dotes
Jun 5 at 22:58






@NateStrickland I think you're right that it's allowed to make your own extension cords, I thought it was a NEC thing but it's just dumb OSHA guidelines which don't really apply here.

– Dotes
Jun 5 at 22:58





5




5





@Dotes -- can you give an OSHA or NEC cite on it being forbidden to have an inlet/outlet pair that's powered up by a cord-and-plug connection to a UPS?

– ThreePhaseEel
Jun 6 at 1:46





@Dotes -- can you give an OSHA or NEC cite on it being forbidden to have an inlet/outlet pair that's powered up by a cord-and-plug connection to a UPS?

– ThreePhaseEel
Jun 6 at 1:46













This is only needed on very long distances. On just a few meters, wiring everything yourself is perfectly fine.

– Overmind
Jun 7 at 7:55





This is only needed on very long distances. On just a few meters, wiring everything yourself is perfectly fine.

– Overmind
Jun 7 at 7:55


















draft saved

draft discarded















































Thanks for contributing an answer to Home Improvement Stack Exchange!


  • Please be sure to answer the question. Provide details and share your research!

But avoid


  • Asking for help, clarification, or responding to other answers.

  • Making statements based on opinion; back them up with references or personal experience.

To learn more, see our tips on writing great answers.




draft saved


draft discarded














StackExchange.ready(
function ()
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdiy.stackexchange.com%2fquestions%2f166657%2fgetting-ups-power-from-one-room-to-another%23new-answer', 'question_page');

);

Post as a guest















Required, but never shown





















































Required, but never shown














Required, but never shown












Required, but never shown







Required, but never shown

































Required, but never shown














Required, but never shown












Required, but never shown







Required, but never shown









Popular posts from this blog

Tamil (spriik) Luke uk diar | Nawigatjuun

Align equal signs while including text over equalitiesAMS align: left aligned text/math plus multicolumn alignmentMultiple alignmentsAligning equations in multiple placesNumbering and aligning an equation with multiple columnsHow to align one equation with another multline equationUsing \ in environments inside the begintabularxNumber equations and preserving alignment of equal signsHow can I align equations to the left and to the right?Double equation alignment problem within align enviromentAligned within align: Why are they right-aligned?

Where does the image of a data connector as a sharp metal spike originate from?Where does the concept of infected people turning into zombies only after death originate from?Where does the motif of a reanimated human head originate?Where did the notion that Dragons could speak originate?Where does the archetypal image of the 'Grey' alien come from?Where did the suffix '-Man' originate?Where does the notion of being injured or killed by an illusion originate?Where did the term “sophont” originate?Where does the trope of magic spells being driven by advanced technology originate from?Where did the term “the living impaired” originate?